2024年4月9日发(作者:)
ATR
建筑2%
ATR J 0901图集
昆明奥琨装饰工程有限公司
复合材料轻质隔墙建筑构造
目 录
说明····················································································1—2
ATR标准板、规格图········································································3
ATR板立面及剖面图······································································4—6
ATR板与板连接节点·············································································7
ATR板与墙、柱、梁板连接节点·······························································8
ATR板单、双层排列图·······································································9
ATR节点安装构件示意图······································································10
ATR墙上设备安装节点·········································································11—12
ATR附录:板原材料、技术 性能、安装要求······················································13—15
建筑2%
说 明
1.编制依据
1.1中国建筑标准设计 研究所图集 03J113
1.2房屋建筑制图统一标准 GB/T5001-2001
1.3ATR复合材料轻质隔墙 板 Q/KAK01-2005
1.4建筑设计防火规范 GBJ16-87
1.5住宅内隔墙 轻质条板 JG/T3029-1995
1.6民用建筑节能设计标准 JGJ26-95
1.7民用建筑工程室内环境污染控制规范 GB50325-2001
1.8建筑装饰装修工程质量验收统一标准 GB50201-2001
1.9建筑工程施工质量验收统一标准 GN50300-2001
1.10建筑材料放射性核素限量 GB6566-201
2.概述
2.1本图集ATR复合材料轻质隔墙板具有重量轻、强度高、防
火、隔声、防辐射 、可加工、施工方使等优点。
2.2 ATR复合材料轻质隔板是以锯未、麦秸、稻草、玉米杆等
植物秸杆中的辅助材料,加入以轻烧镁粉、氯化镁、稳定剂、
改性剂等为原料配制的粘合剂。以中碱玻纤为增强材料 制成
的中空型轻质隔墙板。
3.适用范围
本图集适用于新建、改造、扩建公共建筑 和居住建筑工程中
的非承重内隔墙、内部隔断;框架结构内填 充墙。
建筑2%
4.设计要求
4.1隔声;条板墙 体厚度应满足建筑 隔声功能要求,分户墙
的空气声计权隔声量应≥45dB,宣做双排板的间距一般为10mm
—50mm,作为空气隔声层或填 入吸声材料,如玻璃棉、岩棉
等。
双层条板墙体用于分户墙时,所选用条板的厚度不宜小于
60mm。亦可选用隔声性能符合要求的单层条板、复合条板,其
厚度不应小于120mm。
分室墙空气声计权隔声量应≥35dB。条板用做户内分室隔墙
时,其厚度不宜小于90mm。
4.2防火;设计应采用双层板隔墙构造,可按本图集附表中所
列条板的防火性能选用。
4.3抗震措施。在非抗震地区。条板隔墙与主体结构、顶板和
地面连接采用刚性连接方法;在抗震高防烈度8度和8度以下
地区采用刚性与柔性结合的方法连接固定。
4.4防潮防水:在潮湿环境下安装条板隔墙,墙体设计应有防
潮及防水措施;沿隔墙设计水池、水箱面盆等设备时,墙面应
做涂刷防水涂料等防水设计。
4.5电气设计 :电气线路可作明线设计 ,布置于墙面。亦可
作暗线设计,利用隔墙板孔敷设线路,开关及插座可作相应设
计或暗装设计。
使用实心条板、双层板时,可开槽设计敷设计敷设管线,但槽
深、槽宽不得超过30mm,严禁在墙板两面相同位置同时开槽。
4.6吊挂:隔墙板需要吊挂 重物,应根据使用要求设计埋件,
设计吊挂点的间距应≥300mm,单点吊挂力应≤1000N。
4,7门窗框板安装;位于门、窗框和顶部的门框板、窗框板、
1